BNC 3 Piece Construction

Termination Instructions
for cable types RG-58, 59, 62, 214, & 225

4A.gif

TNC 3 Piece Construction

Termination Instructions
for cable types RG-58, 59, 62, 213, & 225

4B.gif

Mini UHF 3 Piece Construction

Termination Instructions
for cable types RG-58, 59, 62, 213, & 225

4C.gif

Step 1

4D1.gif Trim cable as shown, being careful not to nick the inner conductor or braid.

Step 2

4D2.gif Slip crimp sleeve over cable. Place inner conductor into contact. Note that the end of contact and inner dielectric must be butting and square. Crimp with appropriate tool.

Step 3

4D3.gif Flair outer braid and gently but firmly push the contact into the connector housing until a gentle snap is felt, indicating the contact is in place. Slip the crimp sleeve in place, butting the flange against the connector body and crimp with appropriate tool.